|
photo 02:
|
photo 04:
|
photo 05:
|
photo 07:
|
photo 08:
|
| bmp (~6Mb), gif (~580b) | bmp (~6Mb), gif (~530kb) | bmp (~6Mb), gif (~560kb) | bmp (~6Mb), gif (~460b) | bmp (~6Mb), gif (~470kb) |
| test setup in Glasgow lab | data acquisition MAC (left) and stage control PC (right) | setup in black box with single MaPMT mounted on xy-stages and LED/light guiding fiber light source | MaPMT R7600-03-M64 and singe socket (side view) | MaPMT R7600-03-M64 and singe socket (side view) |
|
photo 09:
|
photo 10:
|
photo 14:
|
photo 15:
|
photo 16:
|
| bmp (~6Mb), gif (~440kb) | bmp (~6Mb), gif (~480kb) | bmp (~6Mb), gif (~310kb) | bmp (~6Mb), gif (~350kb) | bmp (~6Mb), gif (~340kb) |
| MaPMT R7600-03-M64 and singe socket (bottom view), pin layout | MaPMT R7600-03-M64 and singe socket (top view), pixel layout | MaPMT R7600-03-M64 and singe socket | MaPMT mounted on xy-stages, light source apart from photocathode | MaPMT mounted on xy-stages, light source adjusted on pixel |
|
photo 01:
|
photo 02:
|
photo 03:
|
photo 04:
|
photo 05:
|
| bmp (~6Mb), gif (~640kb) | bmp (~6Mb), gif (~330kb) | bmp (~6Mb), gif (~580kb) | bmp (~6Mb), gif (~620kb) | bmp (~6Mb), gif (~640kb) |
| array of 3x3 MaPMT mounted on Hamamatsu bleeder board | bleeder board with MaPMT mounted in testbeam gadget | bleeder board and boards "B" mounted in testbeam gadget | testbeam cave with full scale RICH 1 vessel and MaPMT array mounted | fast readout crew at RICH 1 vessel with mounted setup |
|
photo 06:
|
photo 07:
|
photo 08:
|
photo 09:
|
photo 10:
|
| bmp (~6Mb), gif (~400kb) | bmp (~6Mb), gif (~580kb) | bmp (~6Mb), gif (~570kb) | bmp (~6Mb), gif (~600kb) | bmp (~6Mb), gif (~560kb) |
| board "B" and "int" board mounted together with array of MaPMTs in testbeam box | photodetector array tilted with respect to normal incidence of photons | bleeder boards: Hamamatsu (left) and Cambridge (right), MaPMT side | bleeder boards: Hamamatsu (left) and Cambridge (right), Kapton side | Hamamatsu bleeder board, Kaptons mounted |
|
photo 11:
|
photo 12:
|
photo 13:
|
photo 14:
|
photo 15:
|
| bmp (~2Mb), gif (~380kb) | bmp (~6Mb), gif (~370kb) | bmp (~6Mb), gif (~660kb) | bmp (~6Mb), gif (~510kb) | bmp (~6Mb), gif (~660kb) |
| test of Cambridge bleeder board | test of Cambridge bleeder board | Cambridge bleeder board: MaPMT side, 16 divider chains | Cambridge bleeder board: side view | Cambridge bleeder board: Kapton side |
|
photo 16:
|
photo 17:
|
photo 18:
|
photo 20:
|
photo 21:
|
| bmp (~6Mb), gif (~590kb) | bmp (~6Mb), gif (~340kb) | bmp (~6Mb), gif (~360kb) | bmp (~6Mb), gif (~630kb) | bmp (~6Mb), gif (~550kb) |
| the "tin can" to measure charged particles traversing an MaPMT (with CAMAC readout); background: the silicon telescope used for the "radiology" of the MaPMT | mount of a MaPMT in the "tin can" (here with a quarz lens in addition) | the "tin can" mounted in Helmholz coils (here with the B-field along the longitudinal PMT axis) | photodetector array with quarz lenses in addition mounted on a sliding unit (4 lenses have blackened sides) | mount of a MaPMT in the "tin can" with additional mu-metal shielding |
|
photo 22: (digital camera)
|
photo 23: (digital camera)
|
photo 24: (digital camera)
|
photo 25: (digital camera)
|
photo 26: (digital camera)
|
| jpg (~200kb), gif (~450kb) | jpg (~300kb), gif (~670kb), | jpg (~300kb), gif (~700kb), | jpg (~300kb), gif (~660kb), | jpg (~300kb), gif (~680kb), |
| MaPMT, single socket and quarz lens | tilted photodetector array with fast readout in opened testbeam box | Franz with photodetector array | Marco with photodetector array | array of MaPMT, Cambridge bleeder board and fast readout (board "B" and "int" board) |
|
photo 27: (digital camera)
|
photo 28: (digital camera)
|
photo 29: (digital camera)
|
photo 30: (digital camera)
|
|
| jpg (~300kb), gif (~600kb), | jpg (~300kb), gif (~610kb), | jpg (~300kb), gif (~640kb), | jpg (~200kb), gif (~490kb), | |
| MaPMT array with mounted quarz lenses, sensitive area viewed through the fron face of the lenses | the "tin can" mounted in Helmholz coils (here with the B-field along a transversal PMT axis) | Marco with the setup for the magnetic field measurements | "tin can" with mounted "old Genova tube", mu-metal shield and pin hole array used to mask the pixel of the MaPMT |
|
photo 01:
|
photo 02:
|
photo 03:
|
photo 04:
|
photo 05:
|
| bmp (~930kb), gif (~160b) | bmp (~930kb), gif (~150kb) | bmp (~930kb), gif (~140kb) | bmp (~930kb), gif (~140b) | bmp (~930kb), gif (~140kb) |
| test setup in Edinburgh lab with stage control PC (left) and data acquisition MAC->CAMAC (right) | data acquisition system with dark box (right) | data acquisition system with dark box (open) | stage driver program (left) and acquired histogram from MaPMT (right) | XY-stage setup in dark box |
|
photo 06:
|
photo 07:
|
photo 08:
|
photo 09:
|
photo 10:
|
| bmp (~930kb), gif (~140b) | bmp (~930kb), gif (~140kb) | bmp (~930kb), gif (~150kb) | bmp (~930kb), gif (~140b) | bmp (~930kb), gif (~130kb) |
| XY-stage setup with mounted MaPMT on single socket | LED light focussing setup in front of MaPMT window | single MaPMT base and termination of unused channels | new (mechanically stable!) version of the Hamamatsu bleeder board with one MaPMT mounted | new (mechanically stable!) version of the Hamamatsu bleeder board |
|
photo 11:
|
photo 12:
|
|||
| bmp (~930kb), gif (~130kb) | bmp (~930kb), gif (~130kb) | |||
| MaPMT mounted on Hamamatsu bleeder board | single base with altered resitor chain |